With the cooperation of a team of skilled and dedicated professionals, we have emerged as one of the leading manufacturers and suppliers of NOX Analyzer. These analyzers are used for tuning boilers & furnaces by measuring nitric oxide as well as for detection of gas leakages. To comply with the set industrial norms, we use best quality of raw materials and components, sourced from the most reliable vendors to manufacture the analyzer. We offer our NOX Analyzer at the pocket friendly prices
Features:
Accurate analysis
Quality approved
Easy to use
TPI 714 Combustion Flue Gas Analyzer With Nitric Oxide for Boiler Maintenance and Efficiency Analyzer with Data logging and Optional Infrared Printer.
TPI 714 Boiler Flue Gas Combustion Analyzer with NO/NOx
Applications: Gases Range Resolution Accuracy Oxygen 0 to 25% 0.1% ñ 0.3% Carbon Monoxide 0 to 10,000 ppm 1 ppm ñ 5 ppm or 5% Nitric Oxide 0 to 5000 ppm 0.1% ñ 5 ppm or 5% Carbon Dioxide 0 to 25% 0.1% Calculated NOx 0 to 5250 ppm 1 ppm Calculated CO/CO2 Ratio 0 to 0.999 0.001 Calculated Combustion Eff. 0 to 100% 0.1% Calculated
ââ¬Â¢ Tuning of residential and furnaces and domestic boilers
ââ¬Â¢ Ambient and stack testing for Carbon Monoxide
ââ¬Â¢ Carbon Monoxide safety measurements in and around combustion sources
ââ¬Â¢ Measure NO and calculates NOx
ââ¬Â¢ Detecting gas leak in gas lines and around gas fueled appliances
ââ¬Â¢ Dual input differential manometer with 3 selectable units of measure: kPa, mBar, inH20
Features:
ââ¬Â¢ Measure Oxygen, Carbon Monoxide, Nitric Oxide, Calculate NOx, CO/CO2 Ratio
ââ¬Â¢ Calculates Boiler Combustion Efficiency
ââ¬Â¢ Store function to save up to 50 readings
ââ¬Â¢ Data Logging with time and date stamp
ââ¬Â¢ Pump driven for fast response
ââ¬Â¢ Built-in differential manometer with 0.001" H2O resolution
ââ¬Â¢ Built-in differential thermometer
ââ¬Â¢ Ten selectable fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
ââ¬Â¢ Push on fittings for fast and easy use
ââ¬Â¢ Will not shut off if 15ppm CO is present for increased safety
ââ¬Â¢ Large easy to read backlit display
ââ¬Â¢ Optional A740 IR printer available for hard copies of test results
Measurement Parameters
Specifications:
Carbon Monoxide (CO) Measurement Range: 0 to 10,000 ppm
Resolution: 1 ppm
Accuracy: ñ5ppm or 5% of reading whichever is greater
Oxygen (02) Measurement Range: 0 to 25%
Resolution: 0.1%
Accuracy: ñ0.3%
Carbon Dioxide (CO2) Range: 0 to 25%
Resolution: 0.1%
Calculated Value
Nitric Oxide Measurement Range: 0 to 5,000ppm
Resolution: 1ppm
Accuracy: <100ppm: ñ5ppm <1000ppm ñ5% >1000ppm: ñ10ppm
NOX Measurement Range: 0 to 5,250
Resolution: 1ppm
Calculated Value
Temperature Measurement Range: -40 to 1472ðF (-40 to 800ðC)
Resolution: 1ðF or ðC
Accuracy: (K-type) ñ0.3%, ñ2ðF or ñ1ðC
Draft/Pressure Measurement Selectable Ranges mBar, kPa, and inH2O
Ranges: -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20
Resolution: 0.01mBar
Accuracy: ñ0/5% fsd
Gross/Net Efficiency Range: 0 to 100%
Resolution: 0.1%
Calculated Value
CO/CO2 Ratio Range: 0 to 0.999
Resolution: 0.001
Calculated Value
Instrument Specifications
Operating Temperature: 14ðF to 122ðF (-10ðC to 50ðC)
Charger Input Voltage: 110V to 230V (50/60Hz)
Selectable Fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
Display Type: Backlit 3 line LCD
Data Storage: 10 Locations
Data Logging: Yes (5 pages)
Print Capability: Yes, via optional IR printer (A740)
PC Communication: Yes via optional IR adapter (A767)
Date & Time Function: 24 Hour Real Time Clock
Dimensions: 200mm x 90mm x 60mm
Weight: 500g
Conformity: BS7927 (and the draft BS7967)
S. L. TECHNOLOGIES